Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Arterioscler Thromb Vasc Biol ; 44(4): 954-968, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38385292

RESUMO

BACKGROUND: Venous thromboembolism is a major health problem. After thrombus formation, its resolution is essential to re-establish blood flow, which is crucially mediated by infiltrating neutrophils and monocytes in concert with activated platelets and endothelial cells. Thus, we aimed to modulate leukocyte function during thrombus resolution post-thrombus formation by blocking P-selectin/CD62P-mediated cell interactions. METHODS: Thrombosis was induced by inferior vena cava stenosis through ligation in mice. After 1 day, a P-selectin-blocking antibody or isotype control was administered and thrombus composition and resolution were analyzed. RESULTS: Localizing neutrophils and macrophages in thrombotic lesions of wild-type mice revealed that these cells enter the thrombus and vessel wall from the caudal end. Neutrophils were predominantly present 1 day and monocytes/macrophages 3 days after vessel ligation. Blocking P-selectin reduced circulating platelet-neutrophil and platelet-Ly6Chigh monocyte aggregates near the thrombus, and diminished neutrophils and Ly6Chigh macrophages in the cranial thrombus part compared with isotype-treated controls. Depletion of neutrophils 1 day after thrombus initiation did not phenocopy P-selectin inhibition but led to larger thrombi compared with untreated controls. In vitro, P-selectin enhanced human leukocyte function as P-selectin-coated beads increased reactive oxygen species production by neutrophils and tissue factor expression of classical monocytes. Accordingly, P-selectin inhibition reduced oxidative burst in the thrombus and tissue factor expression in the adjacent vessel wall. Moreover, blocking P-selectin reduced thrombus density determined by scanning electron microscopy and increased urokinase-type plasminogen activator levels in the thrombus, which accelerated caudal fibrin degradation from day 3 to day 14. This accelerated thrombus resolution as thrombus volume declined more rapidly after blocking P-selectin. CONCLUSIONS: Inhibition of P-selectin-dependent activation of monocytes and neutrophils accelerates venous thrombosis resolution due to reduced infiltration and activation of innate immune cells at the site of thrombus formation, which prevents early thrombus stabilization and facilitates fibrinolysis.


Assuntos
Monócitos , Trombose , Camundongos , Humanos , Animais , Monócitos/patologia , Selectina-P , Células Endoteliais , Tromboplastina , Infiltração de Neutrófilos , Neutrófilos
2.
Plast Reconstr Surg ; 153(1): 130-141, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37014963

RESUMO

BACKGROUND: Free flap-based soft-tissue reconstruction comes at the price of donor-site morbidity. The arteriovenous loop (AVL) technique can overcome this issue by allowing for the de novo generation of axially vascularized soft-tissue flaps from vein grafts embedded into different matrices. Application of the AVL technique has been limited by insufficient long-term volume retention and poor tissue stability. The authors investigated the suitability of a novel human dermal scaffold to improve volume retention and tissue stability. METHODS: AVLs were created in 28 immunocompetent rats and embedded in either decellularized human dermal scaffolds (experimental group, n = 14) (Epiflex) or bovine collagen/elastin matrices (control group, n = 14) (MatriDerm) in subcutaneous polytetrafluoroethylene chambers. The weight and volume of engineered tissues, the extent of angiogenesis, and the proportion of proliferating cells were compared between groups on postoperative days (PODs) 21 and 28 by means of immunohistochemistry and micro-computed tomography. RESULTS: On POD 28, both groups displayed homogeneous microvascular networks on histopathology and micro-computed tomography. Mean microvessel counts and surface areas and the percentage of proliferating cells did not differ between the groups. However, the experimental human scaffold group displayed significantly smaller volume loss and significantly less tissue degradation compared with bovine matrix controls (volume retention, 102% ± 5% versus 27% ± 7% on POD 21, and 79% ± 12% versus 12% ± 7% on POD 28, respectively; P < 0.0001). CONCLUSION: Compared with bovine matrices, decellularized human scaffolds allow for superior volume retention and tissue stability of de novo engineered soft-tissue AVL flaps in rats. CLINICAL RELEVANCE STATEMENT: AVLs allow for the de novo generation of vascularized soft-tissue flaps. However, insufficient long-term volume retention is still an issue. The authors' study shows that decellularized human matrices guarantee superior volume stability of de novo grown soft-tissue flaps in rats.


Assuntos
Colágeno , Alicerces Teciduais , Humanos , Ratos , Animais , Bovinos , Microtomografia por Raio-X , Retalhos Cirúrgicos/irrigação sanguínea , Engenharia Tecidual/métodos , Elastina
3.
Acta Biomater ; 173: 351-364, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37984630

RESUMO

Developing biocompatible, non-fouling and biodegradable hydrogels for blood-contacting devices remains a demanding challenge. Such materials should promote natural healing, prevent clotting, and undergo controlled degradation. This study evaluates the biocompatibility and biodegradation of degradable poly(2-hydroxyethyl methacrylate) (d-pHEMA) hydrogels with or without reinforcement with oxidized few-layer graphene (d-pHEMA/M5ox) in a long term implantation in rats, assessing non-desired side-effects (irritation, chronic toxicity, immune response). Subcutaneous implantation over 6 months revealed degradation of both hydrogels, despite slower for d-pHEMA/M5ox, with degradation products found in intracellular vesicles. No inflammation nor infection at implantation areas were observed, and no histopathological findings were detected in parenchymal organs. Immunohistochemistry confirmed d-pHEMA and d-pHEMA/M5ox highly anti-adhesiveness. Gene expression of macrophages markers revealed presence of both M1 and M2 macrophages at all timepoints. M1/M2 profile after 6 months reveals an anti-inflammatory environment, suggesting no chronic inflammation, as also demonstrated by cytokines (IL-α, TNF-α and IL-10) analysis. Overall, modification of pHEMA towards a degradable material was successfully achieved without evoking a loss of its inherent properties, specially its anti-adhesiveness and biocompatibility. Therefore, these hydrogels hold potential as blank-slate for further modifications that promote cellular adhesion/proliferation for tissue engineering applications, namely for designing blood contacting devices with different load bearing requirements. STATEMENT OF SIGNIFICANCE: Biocompatibility, tunable biodegradation kinetics, and suitable immune response with lack of chronic toxicity and irritation, are key features in degradable blood contact devices that demand long-term exposure. We herein evaluate the 6-month in vivo performance of a degradable and hemocompatible anti-adhesive hydrogel based in pHEMA, and its mechanically reinforced formulation with few-layer graphene oxide. This subcutaneous implantation in a rat model, shows gradual degradation with progressive changes in material morphology, and no evidence of local inflammation in surrounding tissue, neither signs of inflammation or adverse reactions in systemic organs, suggesting biocompatibility of degradation products. Such hydrogels exhibit great potential as a blank slate for tissue engineering applications, including for blood contact, where cues for specific cells can be incorporated.


Assuntos
Grafite , Ratos , Animais , Grafite/farmacologia , Poli-Hidroxietil Metacrilato/química , Hidrogéis/farmacologia , Hidrogéis/química , Engenharia Tecidual , Inflamação , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química
4.
Biomater Res ; 27(1): 117, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37978399

RESUMO

BACKGROUND: There is a great clinical need and it remains a challenge to develop artificial soft tissue constructs that can mimic the biomechanical properties and bioactivity of natural tissue. This is partly due to the lack of suitable biomaterials. Hydrogels made from human placenta offer high bioactivity and represent a potential solution to create animal-free 3D bioprinting systems that are both sustainable and acceptable, as placenta is widely considered medical waste. A combination with silk and gelatin polymers can bridge the biomechanical limitations of human placenta chorion extracellular matrix hydrogels (hpcECM) while maintaining their excellent bioactivity. METHOD: In this study, silk fibroin (SF) and tyramine-substituted gelatin (G-TA) were enzymatically crosslinked with human placental extracellular matrix (hpcECM) to produce silk-gelatin-ECM composite hydrogels (SGE) with tunable mechanical properties, preserved elasticity, and bioactive functions. The SGE composite hydrogels were characterized in terms of gelation kinetics, protein folding, and bioactivity. The cyto- and biocompatibility of the SGE composite was determined by in vitro cell culture and subcutaneous implantation in a rat model, respectively. The most cell-supportive SGE formulation was then used for 3-dimensional (3D) bioprinting that induced chemical crosslinking during extrusion. CONCLUSION: Addition of G-TA improved the mechanical properties of the SGE composite hydrogels and inhibited crystallization and subsequent stiffening of SF for up to one month. SGE hydrogels exhibit improved and tunable biomechanical properties and high bioactivity for encapsulated cells. In addition, its use as a bioink for 3D bioprinting with free reversible embedding of suspended hydrogels (FRESH) has been validated, opening the possibility to fabricate highly complex scaffolds for artificial soft tissue constructs with natural biomechanics in future.

5.
Adv Healthc Mater ; 12(23): e2300520, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37173073

RESUMO

Clinically available small-diameter synthetic vascular grafts (SDVGs) have unsatisfactory patency rates due to impaired graft healing. Therefore, autologous implants are still the gold standard for small vessel replacement. Bioresorbable SDVGs may be an alternative, but many polymers have inadequate biomechanical properties that lead to graft failure. To overcome these limitations, a new biodegradable SDVG is developed to ensure safe use until adequate new tissue is formed. SDVGs are electrospun using a polymer blend composed of thermoplastic polyurethane (TPU) and a new self-reinforcing TP(U-urea) (TPUU). Biocompatibility is tested in vitro by cell seeding and hemocompatibility tests. In vivo performance is evaluated in rats over a period for up to six months. Autologous rat aortic implants serve as a control group. Scanning electron microscopy, micro-computed tomography (µCT), histology, and gene expression analyses are applied. TPU/TPUU grafts show significant improvement of biomechanical properties after water incubation and exhibit excellent cyto- and hemocompatibility. All grafts remain patent, and biomechanical properties are sufficient despite wall thinning. No inflammation, aneurysms, intimal hyperplasia, or thrombus formation are observed. Evaluation of graft healing shows similar gene expression profiles of TPU/TPUU and autologous conduits. These new biodegradable, self-reinforcing SDVGs may be promising candidates for clinical use in the future.


Assuntos
Engenharia Tecidual , Enxerto Vascular , Ratos , Animais , Microtomografia por Raio-X , Prótese Vascular , Poliuretanos
6.
Acta Biomater ; 164: 253-268, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37121371

RESUMO

Degradable biomaterials for blood-contacting devices (BCDs) are associated with weak mechanical properties, high molecular weight of the degradation products and poor hemocompatibility. Herein, the inert and biocompatible FDA approved poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogel was turned into a degradable material by incorporation of different amounts of a hydrolytically labile crosslinking agent, pentaerythritol tetrakis(3-mercaptopropionate). In situ addition of 1wt.% of oxidized graphene-based materials (GBMs) with different lateral sizes/thicknesses (single-layer graphene oxide and oxidized forms of few-layer graphene materials) was performed to enhance the mechanical properties of hydrogels. An ultimate tensile strength increasing up to 0.2 MPa (293% higher than degradable pHEMA) was obtained using oxidized few-layer graphene with 5 µm lateral size. Moreover, the incorporation of GBMs has demonstrated to simultaneously tune the degradation time, which ranged from 2 to 4 months. Notably, these features were achieved keeping not only the intrinsic properties of inert pHEMA regarding water uptake, wettability and cytocompatibility (short and long term), but also the non-fouling behavior towards human cells, platelets and bacteria. This new pHEMA hydrogel with degradation and biomechanical performance tuned by GBMs, can therefore be envisioned for different applications in tissue engineering, particularly for BCDs where non-fouling character is essential. STATEMENT OF SIGNIFICANCE: Suitable mechanical properties, low molecular weight of the degradation products and hemocompatibility are key features in degradable blood contacting devices (BCDs), and pave the way for significant improvement in the field. In here, a hydrogel with outstanding anti-adhesiveness (pHEMA) provides hemocompatibility, the presence of a degradable crosslinker provides degradability, and incorporation of graphene oxide reestablishes its strength, allowing tuning of both degradation and mechanical properties. Notably, these hydrogels simultaneously provide suitable water uptake, wettability, cytocompatibility (short and long term), no acute inflammatory response, and non-fouling behavior towards endothelial cells, platelets and bacteria. Such results highlight the potential of these hydrogels to be envisioned for applications in tissue engineered BCDs, namely as small diameter vascular grafts.


Assuntos
Grafite , Hidrogéis , Humanos , Hidrogéis/farmacologia , Poli-Hidroxietil Metacrilato , Grafite/farmacologia , Células Endoteliais , Materiais Biocompatíveis/farmacologia , Água
7.
Bioengineering (Basel) ; 10(3)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36978728

RESUMO

In this study, we aimed to evaluate the human placenta as a source of blood vessels that can be harvested for vascular graft fabrication in the submillimeter range. Our approach included graft modification to prevent thrombotic events. Submillimeter arterial grafts harvested from the human placenta were decellularized and chemically crosslinked to heparin. Graft performance was evaluated using a microsurgical arteriovenous loop (AVL) model in Lewis rats. Specimens were evaluated through hematoxylin-eosin and CD31 staining of histological sections to analyze host cell immigration and vascular remodeling. Graft patency was determined 3 weeks after implantation using a vascular patency test, histology, and micro-computed tomography. A total of 14 human placenta submillimeter vessel grafts were successfully decellularized and implanted into AVLs in rats. An appropriate inner diameter to graft length ratio of 0.81 ± 0.16 mm to 7.72 ± 3.20 mm was achieved in all animals. Grafts were left in situ for a mean of 24 ± 4 days. Decellularized human placental grafts had an overall patency rate of 71% and elicited no apparent immunological responses. Histological staining revealed host cell immigration into the graft and re-endothelialization of the vessel luminal surface. This study demonstrates that decellularized vascular grafts from the human placenta have the potential to serve as super-microsurgical vascular replacements.

8.
Mater Today Bio ; 14: 100262, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35509865

RESUMO

The endothelium plays an important regulatory role for cardiovascular homeostasis. Rapid endothelialization of small diameter vascular grafts (SDVGs) is crucial to ensure long-term patency. Here, we assessed a human placental chorionic extracellular matrix hydrogel (hpcECM-gel) as coating material and compared it to human fibronectin in-vitro. hpcECM-gels were produced from placental chorion by decellularization and enzymatic digestion. Human umbilical vein endothelial cells (HUVECs) were seeded to non-, fibronectin- or hpcECM-gel-coated expanded polytetrafluorethylene (ePTFE) SDVGs. Coating efficiency as well as endothelial cell proliferation, migration and adhesion studies on grafts were performed. hpcECM-gel depicted high collagen and glycosaminoglycan content and neglectable DNA amounts. Laminin and fibronectin were both retained in the hpcECM-gel after the decellularization process. HUVEC as well as endothelial progenitor cell attachment were both significantly enhanced on hpcECM-gel coated grafts. HUVECs seeded to hpcECM-gel depicted significantly higher platelet endothelial cell adhesion molecule-1 (PECAM-1) expression in the perinuclear region. Cell retention to flow was enhanced on fibronectin and hpcECM-gel coated grafts. Since hpcECM-gel induced a significantly higher endothelial cell adhesion to ePTFE than fibronectin, it represents a possible alternative for SDVG modification to improve endothelialization.

9.
ACS Appl Mater Interfaces ; 13(28): 32662-32672, 2021 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-34240610

RESUMO

The lack of small-diameter vascular grafts (inner diameter <5 mm) to substitute autologous grafts in arterial bypass surgeries has a massive impact on the prognosis and progression of cardiovascular diseases, the leading cause of death globally. Decellularized arteries from different sources have been proposed as an alternative, but their poor mechanical performance and high collagen exposure, which promotes platelet and bacteria adhesion, limit their successful application. In this study, these limitations were surpassed for decellularized umbilical cord arteries through the coating of their lumen with graphene oxide (GO). Placental and umbilical cord arteries were decellularized and perfused with a suspension of GO (C/O ratio 2:1) with ∼1.5 µm lateral size. A homogeneous GO coating that completely covered the collagen fibers was obtained for both arteries, with improvement of mechanical properties being achieved for umbilical cord decellularized arteries. GO coating increased the maximum force in 27%, the burst pressure in 29%, the strain in 25%, and the compliance in 10%, compared to umbilical cord decellularized arteries. The achieved theoretical burst pressure (1960 mmHg) and compliance (13.9%/100 mmHg) are similar to the human saphenous vein and mammary artery, respectively, which are used nowadays as the gold standard in coronary and peripheral artery bypass surgeries. Furthermore, and very importantly, coatings with GO did not compromise the endothelial cell adhesion but decreased platelet and bacteria adhesion to decellularized arteries, which will impact on the prevention of thrombosis and infection, until full re-endothetialization is achieved. Overall, our results reveal that GO coating has an effective role in the improvement of decellularized umbilical cord artery performance, which is a huge step toward their application as a small-diameter vascular graft.


Assuntos
Prótese Vascular , Materiais Revestidos Biocompatíveis/química , Grafite/química , Artérias Umbilicais/química , Aderência Bacteriana/efeitos dos fármacos , Plaquetas/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Córion/irrigação sanguínea , Feminino , Células Endoteliais da Veia Umbilical Humana , Humanos , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Placenta/irrigação sanguínea , Gravidez
10.
Acta Biomater ; 134: 276-288, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34329787

RESUMO

Currently available synthetic small diameter vascular grafts reveal low patency rates due to thrombosis and intimal hyperplasia. Biofunctionalized grafts releasing nitric oxide (NO) in situ may overcome these limitations. In this study, a drug-eluting vascular graft was designed by blending polycaprolactone (PCL) with S-nitroso-human-serum-albumin (S-NO-HSA), a nitric oxide donor with prolonged half-life. PCL-S-NO-HSA grafts and patches were fabricated via electrospinning. The fabrication process was optimized. Patches were characterized in vitro for their morphology, drug release, biomechanics, inflammatory effects, cell proliferation, and expression of adhesion molecules. The selected optimized formulation (8%PCL-S-NO-HSA) had superior mechanical/morphological properties with high protein content revealing extended NO release (for 28 days). 8%PCL-S-NO-HSA patches significantly promoted endothelial cell proliferation while limiting smooth muscle cell proliferation. Expression of adhesion molecules (ICAM-1, VCAM-1) and pro-inflammatory macrophage/cytokine markers (CD80, IL-1α, TNF-α) was significantly reduced. 8%PCL-S-NO-HSA patches had superior immunomodulatory properties by up-regulating anti-inflammatory cytokines (IL-10) and M2 macrophage marker (CD163) at final time points. Grafts were further evaluated in a small rodent model as aortic implants up to 12 weeks. Grafts were assessed by magnetic resonance imaging angiography (MRI) in vivo and after retrieval by histology. All grafts remained 100 % patent with no signs of thrombosis or calcification. 8%PCL-S-NO-HSA vascular grafts supported rapid endothelialization, whereas smooth muscle cell proliferation was hampered in earlier phases. This study indicates that 8%PCL-S-NO-HSA grafts effectively support long-term in situ release of bioactive NO. The beneficial effects observed can be promising features for long-term success of small diameter vascular grafts. STATEMENT OF SIGNIFICANCE: Despite extensive research in the field of small diameter vascular graft replacement, there is still no appropriate substitute to autografts yet. Various limitations are associated with currently available synthetic vascular grafts such as thrombogenicity and intimal hyperplasia. Therefore, developing new generations of such conduits has become a major focus of research. One of the most significant signaling molecules that are involved in homeostasis of the vascular system is nitric oxide. The new designed nitric-oxide eluting vascular grafts described in this study induce rapid surface endothelialization and late migration of SMCs into the graft wall. These beneficial effects have potential to improve current limitations of small diameter vascular grafts.


Assuntos
Preparações Farmacêuticas , Enxerto Vascular , Prótese Vascular , Doadores de Óxido Nítrico , Poliésteres , Albumina Sérica Humana
11.
Pharmaceuticals (Basel) ; 14(5)2021 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-34070168

RESUMO

The purpose of this study was to evaluate the ocular pharmacokinetics, bio-distribution and local tolerability of γ-cyclodextrin (γCD) based irbesartan 1.5% eye drops and candesartan 0.15% eye drops after single and multiple topical administration in rabbit eyes. In this randomized, controlled study, a total number of 59 New Zealand White albino rabbits were consecutively assigned to two study groups. Group 1 (n = 31) received irbesartan 1.5% and group 2 (n = 28) candesartan 0.15% eye drops. In both groups, single dose and multiple administration pharmacokinetic studies were performed. Rabbits were euthanized at five predefined time points after single-dose administration, whereas multiple-dose animals were dosed for 5 days twice-daily and then euthanized 1 h after the last dose administration. Drug concentration was measured by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the retinal tissue, vitreous humor, aqueous humor, corneal tissue and in venous blood samples. Pharmacokinetic parameters including maximal drug concentration (Cmax), time of maximal drug concentration (Tmax), half-life and AUC were calculated. To assess local tolerability, six additional rabbits received 1.5% irbesartan eye drops twice daily in one eye for 28 days. Tolerability was assessed using a modified Draize test and corneal sensibility by Cochet Bonnet esthesiometry. Both γCD based eye drops were rapidly absorbed and distributed in the anterior and posterior ocular tissues. Within 0.5 h after single administration, the Cmax of irbesartan and candesartan in retinal tissue was 251 ± 142 ng/g and 63 ± 39 ng/g, respectively. In the vitreous humor, a Cmax of 14 ± 16 ng/g for irbesartan was reached 0.5 h after instillation while Cmax was below 2 ng/g for candesartan. For multiple dosing, the observed Cmean in retinal tissue was 338 ± 124 ng/g for irbesartan and 36 ± 10 ng/g for candesartan, whereas mean vitreous humor concentrations were 13 ± 5 ng/g and <2 ng/g, respectively. The highest plasma concentrations of both irbesartan (Cmax 5.64 ± 4.08 ng/mL) and candesartan (Cmax 4.32 ± 1.04 ng/mL) were reached 0.5 h (Tmax) after single administration. Local tolerability was favorable with no remarkable differences between the treated and the control eyes. These results indicate that irbesartan and candesartan in γCD based nanoparticle eye drops can be delivered to the retinal tissue of the rabbit's eye in pharmacologically relevant concentrations. Moreover, safety and tolerability profiles appear to be favorable in the rabbit animal model.

12.
Biomater Sci ; 9(9): 3362-3377, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33949373

RESUMO

Thrombosis and infection are the leading causes of blood-contacting device (BCD) failure, mainly due to the poor performance of existing biomaterials. Poly(2-hydroxyethyl methacrylate) (pHEMA) has excellent hemocompatibility but the weak mechanical properties impair its use as a bulk material for BCD. As such, pHEMA has been explored as a coating, despite the instability and difficulty of attachment to the underlying polymer compromise its success. This work describes the hydrogel composites made of pHEMA and graphene-based materials (GBM) that meet the biological and mechanical requirements for a stand-alone BCD. Five GBM differing in thickness, oxidation degree, and lateral size were incorporated in pHEMA, revealing that only oxidized-GBM can reinforce pHEMA. pHEMA/oxidized-GBM composites are cytocompatible and prevent the adhesion of endothelial cells, blood platelets, and bacteria (S. aureus), thus maintaining pHEMA's anti-adhesive properties. As a proof of concept, the thrombogenicity of the tubular prototypes of the best formulation (pHEMA/Graphene oxide (GO)) was evaluated in vivo, using a porcine arteriovenous-shunt model. pHEMA/GO conduits withstand the blood pressure and exhibit negligible adhesion of blood components, revealing better hemocompatibility than ePTFE, a commercial material for vascular access. Our findings reveal pHEMA/GO, a synthetic and off-the-shelf hydrogel, as a preeminent material for the design of blood-contacting devices that prevent thrombosis and bacterial adhesion.


Assuntos
Grafite , Poli-Hidroxietil Metacrilato , Animais , Materiais Biocompatíveis/farmacologia , Células Endoteliais , Staphylococcus aureus , Suínos
13.
Mater Sci Eng C Mater Biol Appl ; 124: 112085, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33947575

RESUMO

Conventional electrospun small diameter vascular grafts have a random fiber orientation. In order to achieve mechanical characteristics similar to a native blood vessel, a controllable fiber orientation is of interest. In this study the electrospinning jet was directly controlled by means of an auxiliary, changeable electrostatic field, so that the fibers could be deposited in adjustable orientations. Prostheses with circumferentially, axially, fenestrated and randomly aligned fibers were electrospun on Ø2mm mandrels out of a thermoplastic polyurethane (PUR) and a polylactid acid (PLLA). The impact of the materials and the various preferential fiber orientations on the resulting biomechanics was investigated and compared with that of the native rat aorta in quasistatic and dynamic hoop tensile tests. The test protocol included 3000 dynamic loading cycles in the physiological blood pressure range and ended with a quasistatic tensile test. Any orientation of the fibers in a particular direction resulted in a significant reduction in scaffold porosity for both materials. The standard randomly oriented PUR grafts showed the highest compliance of 29.7 ± 5.5 [%/100 mmHg] and were thus closest to the compliance of the rat aortas, which was 37.2 ± 6.5 [%/100 mmHg]. The maximum tensile force was increased at least 6 times compared to randomly spun grafts by orienting the fibers in the circumferential direction. During the 3000 loading cycles, creeping of the native rat aorta was below 1% whereas the electrospun grafts showed creeping up to 2.4 ± 1.2%. Although the preferred fiber orientations were only partially visible in the scanning electron micrographs, the mechanical effects were evident. The investigations suggest a multi-layer wall structure of the vascular prosthesis, since none of the preferred fiber directions and the materials used could imitate the typical j-shaped mechanical characteristics of the rat aorta.


Assuntos
Prótese Vascular , Enxerto Vascular , Animais , Aorta , Fenômenos Mecânicos , Poliuretanos , Ratos
14.
Front Vet Sci ; 7: 570852, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33195561

RESUMO

Background: Modern surgery demands high-quality and reproducibility. Due to new working directives, resident duty hours have been restricted and evidence exists that pure on-the-job training provides insufficient exposure. We hypothesize that supplemental simulations in animal models provide a realistic training to augment clinical experiences. This study reviews surgical training models, their costs and survey results illustrating academic acceptance. Methods: Animal models were identified by literature research. Costs were analyzed from multiple German and Austrian training programs. A survey on their acceptance was conducted among faculty and medical students. Results: 915 articles were analyzed, thereof 91 studies described in-vivo animal training models, predominantly for laparoscopy (30%) and microsurgery (24%). Cost-analysis revealed single-training costs between 307€ and 5,861€ depending on model and discipline. Survey results illustrated that 69% of the participants had no experience, but 66% would attend training under experienced supervision. Perceived public acceptance was rated intermediate by medical staff and students (4.26; 1-low, 10 high). Conclusion: Training in animals is well-established and was rated worth attending in a majority of a representative cohort to acquire key surgical skills, in light of reduced clinical exposure. Animal models may therefore supplement the training of tomorrow's surgeons to overcome limited hands-on experience until virtual simulations can provide such educational tools.

15.
Acta Biomater ; 116: 246-258, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-32871281

RESUMO

Vascular grafts with a diameter of less than 6 mm are made from a variety of materials and techniques to provide alternatives to autologous vascular grafts. Decellularized materials have been proposed as a possible approach to create extracellular matrix (ECM) vascular prostheses as they are naturally derived and inherently support various cell functions. However, these desirable graft characteristics may be limited by alterations of the ECM during the decellularization process leading to decreased biomechanical properties and hemocompatibility. In this study, arteries from the human placenta chorion were decellularized using two distinct detergents (Triton X-100 or SDS), which differently affect ECM ultrastructure. To overcome biomechanical strength loss and collagen fiber exposure after decellularization, riboflavin-mediated UV (RUV) crosslinking was used to uniformly crosslink the collagenous ECM of the grafts. Graft characteristics and biocompatibility with and without RUV crosslinking were studied in vitro and in vivo. RUV-crosslinked ECM grafts showed significantly improved mechanical strength and smoothening of the luminal graft surfaces. Cell seeding using human endothelial cells revealed no cytotoxic effects of the RUV treatment. Short-term aortic implants in rats showed cell migration and differentiation of host cells. Functional graft remodeling was evident in all grafts. Thus, RUV crosslinking is a preferable tool to improve graft characteristics of decellularized matrix conduits.


Assuntos
Prótese Vascular , Células Endoteliais , Animais , Artérias , Matriz Extracelular , Humanos , Ratos , Riboflavina/farmacologia , Engenharia Tecidual
16.
J Mech Behav Biomed Mater ; 112: 104077, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32942230

RESUMO

An assessment tool to evaluate the degradation of biodegradable materials in a more physiological environment is still needed. Macrophages are critical players in host response, remodeling and degradation. In this study, a cell culture model using monocyte-derived primary macrophages was established to study the degradation, macro-/micro-mechanical behavior and inflammatory behavior of a new designed, biodegradable thermoplastic polyurethane (TPU) scaffold, over an extended period of time in vitro. For in vivo study, the scaffolds were implanted subcutaneously in a rat model for up to 36 weeks. TPU scaffolds were fabricated via the electrospinning method. This technique provided a fibrous scaffold with an average fiber diameter of 1.39 ± 0.76 µm and an average pore size of 7.5 ± 1.1 µm. The results showed that TPU scaffolds supported the attachment and migration of macrophages throughout the three-dimensional matrix. Scaffold degradation could be detected in localized areas, emphasizing the role of adherent macrophages in scaffold degradation. Weight loss, molecular weight and biomechanical strength reduction were evident in the presence of the primary macrophage cells. TPU favored the switch from initial pro-inflammatory response of macrophages to an anti-inflammatory response over time both in vitro and in vivo. Expression of MMP-2 and MMP-9 (the key enzymes in tissue remodeling based on ECM modifications) was also evident in vitro and in vivo. This study showed that the primary monocyte-derived cell culture model represents a promising tool to characterize the degradation, mechanical behavior as well as biocompatibility of the scaffolds during an extended period of observation.


Assuntos
Poliuretanos , Enxerto Vascular , Animais , Técnicas de Cultura de Células , Macrófagos , Monócitos , Ratos , Engenharia Tecidual , Alicerces Teciduais
17.
J Mech Behav Biomed Mater ; 104: 103652, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32174410

RESUMO

AIM: For the proper function of small diameter vascular grafts their mechanical properties are essential. A variety of testing methods and protocols exists to measure tensile strength, compliance and viscoelastic material behavior. In this study the impact of the measurement protocol in hoop tensile tests on the measured compliance and tensile strength was investigated. METHODS: Vascular grafts made out of two different materials, a thermoplastic polyurethane (PUR) and polylactid acid (PLLA), with three different wall thicknesses were produced by electrospinning. Samples were tested with a measurement protocol that allowed the comparison of dynamic sample loading to a common quasistatic tensile test. Influence of measurement temperature, preconditioning cycles and the influence of a high number of loading cycles was also investigated. Compliance and tensile strength were evaluated and compared between the different samples and the different load cases. RESULTS: In all samples a significant difference in the measured compliance was seen between an unloaded sample and a sample that was already in a preloaded state. For example in the PUR group with 100 µm wall thickness at 37 °C, the first compliance was 32.6 ± 9.6%/100 mmHg, which reduced to 15.4 ± 2.9%/100 mmHg at preloaded state. The PLLA group showed 7.5 ± 4.3%/100 mmHg vs. 0.94 ± 0.11%/100 mmHg respectively. The measurements showed the importance of dynamic testing, as the samples viscoelastic behavior had a considerable influence on the measured compliance. The quasistatic ultimate tensile test alone was not able to predict the sample's in vivo compliance. The measurement temperature had a significant influence on tensile strength and compliance. Both, the number of preconditioning cycles and the high number of loading cycles had a minor influence on the sample's compliance. CONCLUSION: With a quasistatic tensile tests alone, overestimated compliance values are measured in viscoelastic electrospun vascular samples, therefore dynamic loading cycles are required. Measurements at 37 °C are mandatory, as temperature has a significant influence on the mechanical properties.


Assuntos
Bioprótese , Prótese Vascular , Teste de Materiais , Poliuretanos , Temperatura , Resistência à Tração
18.
Biomacromolecules ; 21(2): 376-387, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-31718163

RESUMO

We report biodegradable thermoplastic polyurethanes for soft tissue engineering applications, where frequently used carboxylic acid ester degradation motifs were substituted with carbonate moieties to achieve superior degradation properties. While the use of carbonates in soft blocks has been reported, their use in hard blocks of thermoplastic polyurethanes is unprecedented. Soft blocks consist of poly(hexamethylene carbonate), and hard blocks combine hexamethylene diisocyanate with the newly synthesized cleavable carbonate chain extender bis(3-hydroxypropylene)carbonate (BHPC), mimicking the motif of poly(trimethylene carbonate) with highly regarded degradation properties. Simultaneously, the mechanical benefits of segmented polyurethanes are exploited. A lower hard block concentration in BHPC-based polymers was more suitable for vascular grafts. Nonacidic degradation products and hard block dependent degradation rates were found. Implantation of BHPC-based electrospun degradable vascular prostheses in a small animal model revealed high patency rates and no signs of aneurysm formations. Specific vascular graft remodeling and only minimal signs of inflammatory reactions were observed.


Assuntos
Materiais Biocompatíveis/química , Prótese Vascular , Cimento de Policarboxilato/química , Poliuretanos/química , Animais , Aorta/patologia , Aorta/cirurgia , Fenômenos Biomecânicos , Isocianatos/química , Espectroscopia de Ressonância Magnética , Teste de Materiais , Microscopia Eletrônica de Varredura , Implantação de Prótese , Ratos Sprague-Dawley , Espectroscopia de Infravermelho com Transformada de Fourier
19.
Eur J Vasc Endovasc Surg ; 59(4): 643-652, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31874809

RESUMO

OBJECTIVE: Biodegradable materials for in situ vascular tissue engineering could meet the increasing clinical demand for sufficient synthetic small diameter vascular substitutes in aortocoronary bypass and peripheral vascular surgery. The aim of this study was to design a new degradable thermoplastic polycarbonate urethane (dPCU) with improved biocompatibility and optimal biomechanical properties. Electrospun conduits made from dPCU were evaluated in short and long term follow up and compared with expanded polytetrafluoroethylene (ePTFE) controls. METHODS: Both conduits were investigated prior to implantation to assess their biocompatibility and inflammatory potential via real time polymerase chain reaction using a macrophage culture. dPCU grafts (n = 28) and ePTFE controls (n = 28) were then implanted into the infrarenal abdominal aorta of Sprague-Dawley rats. After seven days, one, six, and 12 months, grafts were analysed by histology and immunohistochemistry (IHC) and assessed biomechanically. RESULTS: Anti-inflammatory signalling was upregulated in dPCU conduits and increased significantly over time in vitro. dPCU and ePTFE grafts offered excellent long and short term patency rates (92.9% in both groups at 12 months) in the rat model without dilatation or aneurysm formation. In comparison to ePTFE, dPCU grafts showed transmural ingrowth of vascular specific cells resulting in a structured neovessel formation around the graft. The graft material was slowly reduced, while the compliance of the neovessel increased over time. CONCLUSION: The newly designed dPCU grafts have the potential to be safely applied for in situ vascular tissue engineering applications. The degradable substitutes showed good in vivo performance and revealed desirable characteristics such as biomechanical stability, non-thrombogenicity, and minimal inflammatory response after long term implantation.


Assuntos
Implantes Absorvíveis , Nanofibras/uso terapêutico , Cimento de Policarboxilato/farmacologia , Tempo , Implantes Absorvíveis/efeitos adversos , Animais , Materiais Biocompatíveis/metabolismo , Implante de Prótese Vascular , Politetrafluoretileno/farmacologia , Ratos Sprague-Dawley , Reimplante/métodos , Uretana/farmacologia , Grau de Desobstrução Vascular/efeitos dos fármacos
20.
Biomaterials ; 177: 14-26, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29885585

RESUMO

Small diameter vascular grafts from human placenta, decellularized with either Triton X-100 (Triton) or SDS and crosslinked with heparin were constructed and characterized. Graft biochemical properties, residual DNA, and protein composition were evaluated to compare the effect of the two detergents on graft matrix composition and structural alterations. Biocompatibility was tested in vitro by culturing the grafts with primary human macrophages and in vivo by subcutaneous implantation of graft conduits (n = 7 per group) into the flanks of nude rats. Subsequently, graft performance was evaluated using an aortic implantation model in Sprague Dawley rats (one month, n = 14). In situ graft imaging was performed using MRI angiography. Retrieved specimens were analyzed by electromyography, scanning electron microscopy, histology and immunohistochemistry to evaluate cell migration and the degree of functional tissue remodeling. Both decellularization methods resulted in grafts of excellent biocompatibility in vitro and in vivo, with low immunogenic potential. Proteomic data revealed removal of cytoplasmic proteins with relative enrichment of ECM proteins in decelluarized specimens of both groups. Noteworthy, LC-Mass Spectrometry analysis revealed that 16 proteins were exclusively preserved in Triton decellularized specimens in comparison to SDS-treated specimens. Aortic grafts showed high patency rates, no signs of thrombus formation, aneurysms or rupture. Conduits of both groups revealed tissue-specific cell migration indicative of functional remodeling. This study strongly suggests that decellularized allogenic grafts from the human placenta have the potential to be used as vascular replacement materials. Both detergents produced grafts with low residual immunogenicity and appropriate mechanical properties. Observed differences in graft characteristics due to preservation method had no impact on successful in vivo performance in the rodent model.


Assuntos
Artérias/química , Prótese Vascular , Matriz Extracelular/química , Placenta/irrigação sanguínea , Proteínas/análise , Alicerces Teciduais/química , Animais , Aorta/cirurgia , Fenômenos Biomecânicos , Implante de Prótese Vascular , Córion/irrigação sanguínea , Matriz Extracelular/ultraestrutura , Proteínas da Matriz Extracelular/análise , Feminino , Humanos , Masculino , Gravidez , Ratos Nus , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA